How To Program Caddx Nx 8 Wiring

Posted on  by 

NX-848-KIT NX-8E control, NX-148 LED keypad, 16.5 V 40 VA transformer. NX-108E 8-zone LED keypad. NX-116E 16-zone LED keypad. NX-124E 24-zone LED keypad. NX-148E Alphanumeric 48-zone LCD keypad. NX-200 Zone doubling kit (includes one hundred 3.74k and one hundred 6.98k resistors). NX-216E 16-zone expander module. A highly flexible security option that is both easy to install and simple to use, NetworX control panels can accommodate smaller residential applications up to the most demanding commercial security needs. The series includes the NX-4, NX-6, NX-8 and NX-8E control panels.

  1. Caddx Nx 8 Wiring Diagram
  2. How To Program Caddx Nx 8 Wiring System
  3. Caddx Networx Nx 8
Hi Mike,

Do you want to do a 'factory default' on the NX-8 panel? If that is what
you want to do, click the following link for the manual. Go to page 8 and
follow the instructions for 'Loading Factory Defaults' in the center of the
page.

Program

NOTE: Doing this will clear the program, requiring you to program the entire
system from scratch. Please be absolutely certain this is what you want to
do before doing so.

Caddx Nx 8 Wiring Diagram

If all you want is to change the Download Access Code, that is stored in
Location 20. Follow the instructions for changing that value alone.

Another significant code is the 'Go To Program' code, found in location 42.
It's a 4- or 6-digit code. This is the code you use to enter programming
mode.

To change any item, enter programming as follows:

Disarm the system.
Press [*]-[8].
Enter the current 'Go To Program' code.
Press [0]-[#] to program functions of the NX-8 master control panel itself.
Enter the location number you wish to display/alter, followed by the [#]
key.
Enter the desired new data, followed by the [*] key.
After you press the [*] key the program will advance to the next segment.
Change it if needed and press [*] to scroll on.

For more detailed instructions, see page 9 of the manual I referenced above.

Regards,
Robert L Bass

How To Program Caddx Nx 8 Wiring System

ProgramHow

>
Bass Home Electronics
The Online DIY Alarm Store
http://www.Bass-Home.com
4883 Fallcrest Circle
Sarasota, FL 34233
877-722-8900 Sales & Tech Support
941-925-9747 voice (Florida)
941-923-6238 fax
Rober...@home.com
>

Caddx Networx Nx 8


'mtaylor' <t1...@bellsouth.net> wrote in message
news:3a491003.14488445@news.lig.bellsouth.net...